Fig. 6 - DMX Output Pin Assignments.
1
2
3
4
5
12
3 4
4
5 6 7 8
1
2
3
-D
+D
Ground Shield
AC1
AC2
To Port (7)
On Back Of Panel
6
TO DMX
Equipment
5-Pin Female
XLR Connector
Molex Connector
7588 NW 8th Street, Miami, Fl. 33126
Tel: 305-264-8391 Fax: 305-261-6637or 1-877-264-8391
DMX 3 - 8 Channel Controllers
User's Manual - Page 4
Digital Lighting Systems
D - Installation Instructions ( See Figs. 4 & 5 below).
1. Install the OPTIMA in a convenient location. Fig. 4 shows an OPTIMA-DS which has a female XLR connector
mounted on the side of its aluminium enclosure. OPTIMA-DS2 models are mounted in deep single gang masonry
boxes and have a female XLR connector mounted externally (See Fig. 5 below).
2. Provide a standard power outlet with a toggle switch for the wall transformer. Plug the supplied transformer to the
OPTIMA using the Molex connector plugs. The OPTIMA may remain energized at all times. The loads can be turned
off by using the front panel ‘Black-Out’ button.
3. Install the DMX dimmer pack and follow the wiring instructions in its user manual.
4. Connect the OPTIMA to the Dimmer Pack using the DMX cable (DMX-CC-LEN) to either internally or externally
mounted XLR connector. Skip to Operating Instructions.
digitallighting.com
Digital Lighting Systems
Miami, Fl. USA
OPTIMA-DS
MODE
RUN
RATE
MAX.
LEVEL
MIN.
LEVEL
FADE
AUTO
STOP
BLK.
OUT
DIM1
DIM2
DIM3
DIM4
Lighting Animation Controller
9V Wall
Adapter
Molex Plugs
ADDRESS SELECTORS
S1S2
LED OUTPUT
MONITORS
1 2
3
4
INT04
PD408-DMX
To more DMX
Dimmer Packs
OPTIMA-DS2
4 channel logic DMX512
Fade/
Chase
Auto/
Man.
ALL
ON
ALL
OFF
Pattern
Speed
9V Wall
Adapter
To DMX
Dimmer Packs
DMX-CC-LEN
DMX-CC-LEN
Fig. 4 OPTIMA-DS Installation Drawing
Fig. 5 OPTIMA-DS2
Installation Drawing
E - OPTIMA DMX and Power Connections
The OPTIMA panels use a standard 5-Pin Female XLR connector to
connect to DMX equipment as seen in Figs. 4 & 5. They are also
available on request with an unterminated pigtail that plugs into the
back of the unit so that customer may make their own DMX connections
or with a pre-terminated cable with XLR connector to the customer’s
desired length (J8FXLR5-L). An external transformer supplies power via
a 2-pos. Molex type connector.
Power and DMX pin assignments are shown in Fig. 6.
9V Wall
Adapter
J8FXLR5-L - L = Length in feet.
J8FXLR5-L
Molex Plugs
XLR Connectors
OPTIMA-DS
OSUM
Rev. C 06/03
Copyright 2003 Digital Lighting Systems, All rights Reserved Specifications are subject to change without notice. Printed in U.S.A.